Transition Networks’ Industrial Media
Converters are hardened devices designed to reliably operate in harsh
environments such as those found on factory floors, outdoor enclosures or other
hazardous environments.
Features
Auto-Negotiation
AutoCross™
Automatically
detects and configures the twisted pair port on the converter to the correct MDI
or MDI-X configuration.
Link Pass Through
Link Pass Through is a
troubleshooting feature that allows the media converter to monitor both the
fiber and copper RX ports for loss of signal.
Standard (-10°C to 50°C) or
Extended (-40°C to 65°C) operating temperature
Dry Contact Relay Alarm
Output
Dual, Redundant, Auto-Sensing
12-48V DC Power Inputs
Reverse Polarity Power
Input Protection
Overload Current Protection
DIN Rail Mounting and Wall
Mount Brackets Included
Barrel connector interface cable included for
connecting external AC/DC power supply
Specifications
| Standards |
IEEE 802.3™, IEEE 802.3ab,
IEEE 802.3u, IEEE 802.3x, IEEE 802.3z |
| Data
Rate |
Copper: 10/100/1000 Mbps Fiber: 1000 Mbps SFP: 1000 Mbps |
| Fiber Optic Connector Specs |
| Status
LEDs |
PWR 1
(Power): ON =
primary power connected PWR 2 (Power): ON = backup power
connected FAULT: ON = power input failure on PWR1 or PWR2 1000M (port 1): ON = Linked at 1000Mbps LNK/ACT (ports
1-2): ON = Link; FLASHING = data
transmitting |
| Dip
Switches |
1: Enable/Disable Power Alarm 2: Enable/Disable Link Pass
Through |
| Dimensions |
Width: 1.2" [30 mm] Depth: 3.7" [95 mm] Height: 5.5" [140 mm] |
| Ingress
Protection |
IP30 |
| Input
Power |
12 to 48 VDC, 0.2A-0.5A,
redundant inputs with reverse polarity protection; Additional barrel
connector |
| Power
Consumption |
4.9 watts |
| Environment |
-10 to +50°C Std. operating
temp. -40 to +65°C Ext.
operating temp. 5%– 95%
humidity non-condensing 0 – 10,000 feet altitude -40
to +85°C storage temp. |
| Shipping
Weight |
1.4 lbs. [0.64
kg] |
| Safety |
UL, cUL,
CE/EN60950-1 |
| EMI |
CISPR22/EN55022; EN60950
Class A; FCC Class A; CE Mark;CE EN61000-4-2; CE EN61000-4-3; CE
EN-61000-4-4; CE EN61000-4-5; CE EN61000-4-6; CE EN61000-4-8; CE
EN61000-4-11; CE EN61000-4-12; CE EN61000-6-2; CE EN61000-6-4 |
| Environmental
Compliance |
IEC60068-2-32 (Free fall);
IEC60068-2-27 (Shock); IEC60068-2-6 (Vibration) |
| Warranty |
Lifetime |
Especificacoes: